If you are searching for an explosion-proof elevator for a refinery, chemical plant, mine or offshore platform, you will quickly run into two certification names: ATEX and IECEx. Many purchasing teams treat them as interchangeable labels. They are not. Each one affects your contract language, your documentation package, your delivery schedule and, in some countries, whether the elevator may legally be put into service at all.
An elevator is one of the most complex machines in a hazardous plant. It contains motors, brakes, drives, limit switches, lighting, communication devices, travelling cables and moving mechanical parts, all of which can become ignition sources if the surrounding atmosphere contains flammable gas, vapor or combustible dust. A spark from a relay, a hot brake surface or an electrostatic discharge from a car panel can be enough.
Certification is the evidence that these risks were assessed by a competent third party against recognized standards. For a buyer, it is also the document trail that insurers, safety auditors and local authorities will ask for. This article explains how ATEX and IECEx differ, how hazardous area classification drives elevator design, and what to verify before you place an order.
ATEX comes from the French phrase "ATmosphères EXplosibles". In practice it refers to two European Union directives. Directive 2014/34/EU sets the essential health and safety requirements for equipment and protective systems intended for use in potentially explosive atmospheres. Directive 1999/92/EC places obligations on employers to classify hazardous areas and to protect workers on site.
For a manufacturer, ATEX means the product must be assessed under the relevant conformity route, carry the CE mark together with the specific explosion protection marking, and be supplied with an EU declaration of conformity and instructions. For an elevator project in the European Economic Area, ATEX compliance is a legal prerequisite rather than a commercial preference.
IECEx is the International Electrotechnical Commission System for Certification to Standards relating to Equipment for Use in Explosive Atmospheres. It is not a law. It is a voluntary, globally recognized certification scheme built on the IEC 60079 series of standards, with testing and certification carried out by IECEx-recognized test laboratories (ExTL) and certification bodies (ExCB). The result is a Certificate of Conformity, supported by a test report and, for manufacturers, an audited quality assessment.
Because the certificates are public and traceable in the IECEx online database, many oil, gas and petrochemical operators outside Europe use IECEx as their preferred proof of compliance, and a number of national regulators accept it as a basis for local approval.
Both systems are built around the same idea: prevent a flammable atmosphere and an effective ignition source from meeting. Standards define how enclosures withstand internal explosions, how circuit energy is limited, how surface temperatures are controlled and how non-electrical parts such as brakes and bearings are constructed. Without a recognized scheme, "explosion-proof" is only a sales claim. With one, it is a verified and documented property of the equipment.
ATEX is mandatory law for equipment placed on the market in the EU and EEA. IECEx has no legal force by itself; its authority comes from being adopted, referenced or accepted by national authorities and by project owners in their specifications. A buyer in Germany cannot substitute IECEx for ATEX, while a buyer in the Middle East, Southeast Asia or Australia may find IECEx written directly into the tender documents.
Under ATEX, higher-risk categories of equipment require a Notified Body to examine the design and to assess the manufacturer's production quality system. Lower-risk categories can follow simpler internal production control routes. IECEx follows a more uniform pattern: product testing by an ExTL, a certificate issued by an ExCB, and a recurring audit of the manufacturer's quality system through a Quality Assessment Report.
Technically, the two systems overlap heavily. ATEX certification normally relies on harmonized European standards (the EN 60079 series), which are closely aligned with IEC 60079. For non-electrical equipment, the ISO/IEC 80079 series is relevant. The visible difference is in the marking, which tells you exactly what the equipment is allowed to do.
An ATEX label adds the CE mark, the Notified Body number where applicable, the specific Ex symbol, the equipment group and category (for example II 2G), followed by a string like the one above. An IECEx product is identified by its certificate number, which begins with "IECEx" and can be looked up online.
Before comparing certificates, you need to know what the elevator must survive. The owner or safety engineer classifies the site into zones, and that classification determines the category or equipment protection level (EPL) the elevator's components must meet.
Zone 0 is where an explosive gas atmosphere is present continuously or for long periods. Zone 1 is where it is likely to occur occasionally during normal operation. Zone 2 is where it is not likely to occur in normal operation and, if it does, will persist only briefly. Most elevator projects fall into Zone 1 or Zone 2. Elevator equipment is almost never installed in Zone 0, and a hoistway that opens into Zone 0 usually calls for a redesign of the layout.
The same logic applies to combustible dust clouds and layers. Zone 20 has a dust cloud present continuously or for long periods, Zone 21 occasionally, and Zone 22 only rarely and briefly. Grain handling, coal preparation, metal powder, pharmaceutical powders and wood processing are common sources. Dust adds a second problem: layers on hot surfaces can ignite, so enclosure surface temperature limits matter as much as sparks.
Equipment Group I covers underground mines susceptible to methane and coal dust, while Group II covers all other industries. Within Group II, gases are divided into IIA (for example propane), IIB (for example ethylene) and IIC (for example hydrogen and acetylene), with IIC being the most demanding. Dust is divided into IIIA, IIIB and IIIC for combustible flyings, non-conductive dust and conductive dust.
Temperature classes run from T1 (450 °C) down to T6 (85 °C). The maximum surface temperature of any component, including the brake, motor and lamp housings, must stay below the auto-ignition temperature of the gas or dust on site. Specifying "T4" when your process contains carbon disulfide, for instance, would be a serious error. Always confirm the substance data with your process safety team before issuing the elevator specification.
Three protection concepts appear most often in elevator electrical systems. Flameproof enclosures (Ex d) contain an internal explosion and cool the escaping gases through precisely controlled joints. Intrinsic safety (Ex i) limits energy in a circuit so that even a short circuit cannot ignite the atmosphere, which suits sensors, buttons and communication signals. Increased safety (Ex e) uses enhanced insulation, larger clearances and temperature control to avoid arcs and overheating in terminal boxes and similar parts. A properly engineered special elevator combines these methods and keeps each certified component within the limits of its own certificate.
Ask which parts are certified individually (motor, brake, control panel, door operator, lighting, intercom, limit switches, travelling cable) and whether they are marked for the specific zone, gas group and temperature class of your site. Mechanical items matter too: brakes, guide shoes, rope drums and buffers should be built to avoid friction sparks and hot surfaces, for example with non-sparking guide materials and enclosed wet-type friction elements.
Hazardous plants typically move heavy equipment, drums, instruments, spare parts and maintenance teams. Reference designs for explosion-proof freight elevators with a machine room range from 1,000 kg to 10,000 kg, with rated speeds typically between 0.25 and 1.0 m/s. For example, a 2,000 kg unit may use a car of roughly 1,600 x 2,600 mm, while a 5,000 kg unit moves up to car sizes around 2,400 x 3,600 mm. Machine room-less layouts are also available for loads up to 5,000 kg, which can reduce civil work. These values are design references only; the final shaft size, pit depth and overhead height must follow the project drawing.
Also state your operating profile: number of starts per hour, forklift access, ambient temperature range, humidity and whether the elevator must operate during emergency conditions. For high-capacity use, check the structural design of the car floor and sling to avoid sinking under concentrated loads. If you are comparing logistics-oriented models, the freight series elevator range gives a useful baseline for dimensions and capacity.
Explosion protection and ingress protection are separate requirements. Ex certification says nothing about whether water, salt spray or conductive dust will reach live parts. For outdoor refineries, offshore decks and wet process areas, an IP68-class sealing concept with labyrinth shaft seals, corrosion-resistant coatings and drainage design is often necessary. For extremely dusty or damp sites, the IP elevator design approach is a helpful complement, and offshore or coastal projects may also need the corrosion and motion considerations of a marine elevator.
Structural features worth checking include a reinforced car enclosure, anti-impact buffering, anti-static treatment of surfaces and sealed operating components such as buttons and lamps. In coal environments, moisture, dust and high humidity add further demands, which is why dedicated mine elevators are engineered differently from standard industrial lifts.
A serious supplier should be able to provide, before order confirmation and at handover:
Check that the nameplate data matches the paperwork. A certificate that covers a different model, voltage or gas group does not validate the component installed in your elevator.
If the elevator will be installed in an EU or EEA country, ATEX conformity is the legal route. The elevator documentation should include the EU declaration of conformity, and components must carry the appropriate CE and Ex markings. Some European owners also accept IECEx certificates as supporting evidence for individual components, but they remain subject to the directive for the final installation.
For projects in the Middle East, Africa, Asia and Latin America, the tender specification usually decides. Many EPC contractors and operators name IECEx directly or accept either IECEx or ATEX. Regional schemes may add national requirements, so confirm the acceptance rules with the local authority early. Reviewing comparable overseas cases can help you understand how documentation and approvals are typically handled for export projects.
Dual certification is common in multinational projects where the owner is European but the site is outside Europe, or where equipment is manufactured in one region, installed in another and audited under a global company standard. Because the technical requirements overlap, components already certified to IEC 60079 are often easier to certify under both systems, but each certificate must still be issued and maintained separately. Raise this requirement at the inquiry stage, not after fabrication has started.
An offshore platform, a coal mine and a pharmaceutical solvent store do not share the same hazards. Suxun Elevator develops customized explosion-proof elevators for oil and gas, coal and non-coal mines, chemical and pharmaceutical plants, aerospace fueling areas and offshore platforms, based on market research and after-sales feedback. Existing installations can also be upgraded, since old elevators can be retrofitted. You can read more about the company on the about us page or review its certifications.
Explosion protection must not weaken ordinary lift safety, and lift safety devices must not become ignition sources. Safety gear, overspeed protection, door interlocks, buffers and emergency communication all have to work together with the chosen protection concepts. Modern designs add temperature, vibration and gas concentration sensors for early fault warning and remote diagnosis, and can use detectors to coordinate landing doors with forklift traffic. Systematic quality management keeps these integrated features consistent from design to factory testing.
Good support goes beyond shipping a car and a motor. It includes layout drawings for the shaft, pit and machine room, a clear component certificate list, commissioning guidance and maintenance instructions suited to hazardous areas. Buyers can begin with the product manual and the download center, then follow up with a project-specific technical review.
ATEX and IECEx share the same safety goal, but they differ in legal status, procedure and documentation. ATEX is essential for European installations, while IECEx is widely preferred for international oil, gas, chemical and mining projects. The best starting point is always the same: define your hazardous zone, gas or dust group and temperature class, then select an elevator whose every critical component can be traced to a valid certificate.
If you are planning a new installation or a retrofit, share your site classification, load requirements and target markets with our engineers through the contact page, or email sselift@163.com. You can also call +86 189 6928 6006. Please confirm the certification scope required for your project at the inquiry stage so the correct documentation can be planned from the start. For more technical articles, visit our industry news.